JRM

Journal of Radiology in Medicine is an international journal that published original research and articles in all areas of radiology. Its publishes original research articles, review articles, case reports, editorial commentaries, letters to the editor, educational articles, and conference/meeting announcements.

EndNote Style
Index
Original Article
Multidetector computed tomography findings and 3 dimensional volume measurement of ıntraluminal thrombus in abdominal aort aneurysms
Aims: To output imaging findings of intraluminal thrombus (ILT) and calculate its volume exactly with 3 Dimensional (3D) software, in infrarenal abdominal aorta aneurysms (AAA), by multidetector computed tomography (MDCT).
Methods: This was a retrospective study, with patient data included from January 2009 to May 2009 at Turkiye Yüksek İhtisas Hospital Radiology Department. Fifty patients (47 males, 3 females) with a mean age of 67 (47-85) who were referred with a pre-diagnosis of AAA and underwent MDCT were analyzed. Patients with aortic diameter of 30mm or more at the infrarenal level were included in the study. The patients was divided into 3 groups according to ADmax: ? 5cm, 5-7cm and ? 7cm (7). The relationship between parameters such as the widest diameter of the aneurysmatic segment, longitudinal length, location of the ILT and aneurysm volume were evaluated with the amount of ILT calculated by semi-automatic method using MDCT images obtained with 16 and 64-detector CT devices.
Results: The study was conducted on a total of 50 patients with an average age of 67 years (47 – 85), 47 (94%) men and 3 (6%) women. In the aneurysmatic segment, the maximum aortic diameter was measured as mean 5.6 cm (3.7–8.8cm), and longitudinal length was measured as mean 9.8 cm (4.9–17.1cm). Aneurysm volume was calculated as 188.8 cm³ (44.8–670.2 cm³) on average, and ILT volume as an average of 104.3 cm³ (11.8–474.7 cm³). A significant increase in ILT % over 5 cm diameter was found, while ILT % was lower until the maximum aorta diameter reached 5 cm. We found that ILT was concentrated mostly in anterior quadrant in 19 patients (38%).
Conclusion: There is a positive relationship between the thrombus volume(p= 0.0001) and the aneurysm volume (p= 0.0001) and the maximum diameter of the aneurysm. Since the volume measurements in our study are based on a semi-automatic method that completely separates the structures of interest from the rest by adjusting the threshold values, it’s more accurate than 2-dimensional conventional CT measurements based on mathematical calculations in which the thrombus area and the length of the aneurysm in axial sections were used.


1. Scott RA, Ashton HA, Kay DN. Abdominal aortic aneurysm in 4.237 screened patients: prevalence, development and management over 6 years. Br J Surg. 1991;78(9):1122-1125. doi:10.1002/bjs.1800780929
2. Kumar V, Cotran RS, Robbins SL. Basic Pathology- Temel Patoloji. İstanbul: Nobel Tıp Kitabevleri: 2000.
3. Norwood MGA, Lloyd GM, Bown MJ, Fishwick G, London NJ, Sayers RD. Endovascular abdominal aortic aneursym repair. Postgrade Med J. 2007;83(975):21-27. doi:10.1136/pgmj.2006.051177
4. Hans SS, Jareunpoon O, Balasubramaniam M, Zelenock GB. Size and location of thrombus in intact and ruptured abdominal aortic aneurysms. J Vasc Surg. 2005;41(4):584-588. doi:10.1016/j.jvs.2005.01.004
5. Martufi G, Lindquist Liljeqvist M, Sakalihasan N, et al. Local diameter, wall stress, and thrombus thickness ınfluence the local growth of abdominal aortic aneurysms. J Endovasc Ther. 2016;23(6):957-966. doi: 10.1177/1526602816657086
6. Golledge J, Wolanski P, Parr A, Buttner P. Measurement and determinants of infrarenal aortic thrombus volume. Eur Radiol. 2008; 18(9):1987-1994. doi:10.1007/s00330-008-0956-3
7. Pillari G, Chang JB, Zito J, et al. Computed tomography of abdominal aortic aneurysm. An in vivo pathological report with a note on dynamic predictors. Arch Surg. 1988;123(6):727-732. doi:10.1001/archsurg.1988. 01400300073012
8. Speelman L, Schurink GW, Bosboom EM, et al. The mechanical role of thrombus on the growth rate of an abdominal aortic aneurysm. J Vasc Surg. 2010;51(1):19-26. doi:10.1016/j.jvs.2009.08.075
9. Piechota-Polanczyk A, Jozkowicz A, Nowak W, et al. The abdominal aortic aneurysm and ıntraluminal thrombus: current concepts of development and treatment. Front Cardiovasc Med. 2015;2:19. doi:10. 3389/fcvm.2015.00019
10. Guimarães TA, Garcia GN, Dalio MB, Bredarioli M, Bezerra CA, Moriya T. Morphological aspects of mural thrombi deposition residual lumen route in infrarenal abdominal aorta aneurisms. Acta Cir Bras. 2008;23(Suppl 1):151-156. doi:10.1590/s0102-86502008000700024
11. Spanos K, Nana P, Kouvelos G, Mpatzalexis K, Matsagkas M, Giannoukas AD. Anatomical differences between ıntact and ruptured large abdominal aortic aneurysms. J Endovasc Ther. 2020;27(1):117-123. doi:10.1177/1526602819886568
Volume 2, Issue 3, 2025
Page : 49-52